The language of measurement.

Concise definitions aligned with the international vocabulary of metrology and laboratory practice.

22 of 22 terms

Calibration

The operation that, under specified conditions, establishes a relation between the values indicated by a measuring instrument and the corresponding values realised by reference standards, with their uncertainties. Calibration does not itself adjust the instrument.

See also:Metrological traceabilityMeasurement uncertaintyAs-found / as-left

Metrology

The science of measurement and its application, including all theoretical and practical aspects of measurement whatever the field or level of uncertainty.

See also:CalibrationMetrological traceability

Metrological traceability

The property of a measurement result whereby it can be related to a reference through a documented, unbroken chain of calibrations, each contributing to the measurement uncertainty.

See also:CalibrationMeasurement uncertaintyISO/IEC 17025

CMC (Calibration and Measurement Capability)

The smallest uncertainty a laboratory can achieve within its accredited scope when performing a routine calibration of a near-ideal device. A CMC is a laboratory capability statement, not the accuracy of any particular instrument.

See also:Measurement uncertaintyAccuracyISO/IEC 17025

Measurement uncertainty

A non-negative parameter characterising the dispersion of the values that could reasonably be attributed to the measurand. Usually reported as an expanded uncertainty with a stated coverage factor (commonly k = 2).

See also:CMC (Calibration and Measurement Capability)RepeatabilityDecision rule

Accuracy

The closeness of agreement between a measured value and the true value of the measurand. A qualitative concept — it is not expressed as a number, although manufacturers often use the word for a specified maximum error.

See also:PrecisionCMC (Calibration and Measurement Capability)

Precision

The closeness of agreement between repeated measurements of the same quantity under stated conditions. Precision says nothing about closeness to the true value.

See also:AccuracyRepeatabilityReproducibility

Repeatability

Measurement precision under conditions that include the same procedure, operator, instrument, location and a short period of time.

See also:PrecisionReproducibility

Reproducibility

Measurement precision under conditions that include different locations, operators or measuring systems, on the same or similar objects.

See also:RepeatabilityPrecision

Temperature mapping

A documented study that places calibrated sensors throughout a storage or process space to characterise the temperature distribution over time, locate hot and cold spots and confirm that the space stays within its acceptance limits.

See also:Temperature excursionGDP (Good Distribution Practice)PQ (Performance Qualification)

UKAS

The United Kingdom Accreditation Service — the UK's national accreditation body, which assesses laboratories against standards such as ISO/IEC 17025.

See also:ISO/IEC 17025CMC (Calibration and Measurement Capability)

ISO/IEC 17025

The international standard for the competence of testing and calibration laboratories. It covers impartiality, personnel, equipment, metrological traceability, methods, uncertainty, reporting and management-system requirements.

See also:Metrological traceabilityCMC (Calibration and Measurement Capability)UKAS

GDP (Good Distribution Practice)

The quality-system requirements for the wholesale distribution of medicinal products, including temperature control and monitoring during storage and transport.

See also:GMP (Good Manufacturing Practice)Temperature mapping

GMP (Good Manufacturing Practice)

The regulated quality requirements for manufacturing medicinal products so that they are consistently produced and controlled to the required quality standards.

See also:GDP (Good Distribution Practice)IQ (Installation Qualification)OQ (Operational Qualification)PQ (Performance Qualification)

IQ (Installation Qualification)

Documented verification that equipment or a system has been installed according to its specification and the manufacturer's recommendations.

See also:OQ (Operational Qualification)PQ (Performance Qualification)

OQ (Operational Qualification)

Documented verification that installed equipment operates as intended across its anticipated operating ranges.

See also:IQ (Installation Qualification)PQ (Performance Qualification)

PQ (Performance Qualification)

Documented verification that equipment or a system performs consistently under routine conditions of use — for a storage space, often demonstrated by a temperature mapping study.

See also:IQ (Installation Qualification)OQ (Operational Qualification)Temperature mapping

OOT (Out of Trend)

A result that is within specification but does not follow the expected pattern of previous results, prompting investigation before it becomes out of specification.

See also:OOS (Out of Specification)

OOS (Out of Specification)

A result that falls outside the established acceptance criteria or specification limits and requires a documented investigation.

See also:OOT (Out of Trend)Temperature excursion

Temperature excursion

A period during which a monitored temperature is outside its acceptance limits; characterised by its magnitude and duration and assessed for product impact.

See also:Temperature mappingOOS (Out of Specification)

Decision rule

A documented rule describing how measurement uncertainty is accounted for when stating conformity with a specification — for example simple acceptance, or guard banding that reduces the acceptance zone by the uncertainty.

See also:Measurement uncertaintyISO/IEC 17025

As-found / as-left

As-found data are the instrument's readings before any adjustment; as-left data are the readings after adjustment. Both are needed to judge whether measurements made since the previous calibration were affected.

See also:Calibration