Equipment

How to choose a temperature data logger for mapping and monitoring

Match resolution and accuracy to the acceptance criteria, check the calibration offer, and look at memory, battery, export format and response time before price.

2026-09-13 · 2 min read
Equipment

Pt100 tolerance classes explained (IEC 60751)

Class AA, A, B and C define the maximum permissible deviation of a platinum resistance thermometer from the standard curve as a function of temperature. They are tolerances, not uncertainties.

2026-09-13 · 2 min read
Equipment

Thermocouple types and tolerance classes (IEC 60584)

Types K, J, T, N, E and the noble-metal types R, S, B each have defined EMF curves and tolerance classes 1, 2 and 3. Choose by range, environment and required tolerance.

2026-09-13 · 2 min read
Equipment

Thermistors: high sensitivity over a narrow range

NTC thermistors offer very high resolution and stability near ambient, which is why many precision loggers use them. Their non-linearity means calibration at several points and a fitted equation.

2026-09-13 · 2 min read
Equipment

Characterising a dry-block calibrator

Before using a dry block for calibration, measure its axial and radial gradients, stability, loading effect and the effect of insert wear — and repeat periodically.

2026-09-13 · 2 min read
Equipment

Choosing a liquid calibration bath and its fluid

The fluid sets the range, the stirring sets uniformity, and depth sets immersion. Ethanol, water, oil and salt each own a range; safety and cleanliness decide among the overlaps.

2026-09-13 · 2 min read
Equipment

Readouts and bridges for reference thermometers

A reference PRT is only as good as the instrument reading it. Resolution, linearity, measurement current and calibration of the readout all enter the budget.

2026-09-13 · 2 min read
Equipment

Ice point, triple point of water and other fixed points

Fixed points realise defined temperatures without a calibrated reference. The ice point (0 °C, ~±0.002 °C) is accessible to any laboratory; the triple point of water (0.01 °C) is the anchor of ITS-90.

2026-09-13 · 2 min read
Equipment

Infrared thermometers: what they measure and when to trust them

An IR thermometer measures radiance, not temperature. Emissivity, field of view, distance and reflected background all change the reading — which is why they are for screening, not for GDP records.

2026-09-13 · 2 min read
Equipment

Maintaining calibration equipment between calibrations

References drift, baths contaminate, inserts wear, batteries die. A maintenance plan with intermediate checks keeps equipment within its assumed performance and catches failures early.

2026-09-13 · 2 min read