Temperature calibration in practice

Bench-level technique for PRTs, thermocouples and loggers: sources, immersion, self-heating, hysteresis, references and the ice point.

For: Laboratory technicians and engineers performing or specifying temperature calibrations.

  1. 01CalibrationHow to calibrate a Pt100Calibration by comparison against a reference thermometer, and the factors that decide the uncertainty.2 min
  2. 02CalibrationChoosing calibration pointsCalibrate where you measure. Points should bracket the use range and include any temperature where a decision is made.2 min
  3. 03CalibrationLiquid bath versus dry-block calibratorA stirred liquid bath offers the best uniformity; a dry block offers speed, portability and no fluid — the choice is about uncertainty and practicality.2 min
  4. 04CalibrationImmersion depth and stem conductionA probe conducts heat along its stem. Insufficient immersion makes the sensor read closer to room temperature than to the medium.2 min
  5. 05CalibrationSelf-heating in resistance thermometersThe measuring current warms the sensing element. The effect depends on the medium — so calibrate at a current and condition representative of use.2 min
  6. 06CalibrationHysteresis in temperature sensorsA sensor can read differently at the same temperature depending on where it came from. Calibrations that only approach from one direction hide it.2 min
  7. 07CalibrationSelecting a reference thermometerThe reference sets the floor of your uncertainty. Choose it for stability and a calibration uncertainty comfortably below what you need to deliver.2 min
  8. 08CalibrationThe ice-point checkA properly made ice bath gives 0 °C to within a few millikelvin — a cheap, repeatable way to watch a PRT for drift between calibrations.2 min
  9. 09UncertaintyThe reference thermometer's contribution to uncertaintyThe reference contributes its certificate uncertainty, its drift since calibration, and any interpolation or self-heating effects. Together they set the floor of what can be claimed.2 min
  10. 10CalibrationHow temperature data loggers are calibratedLoggers are calibrated as a system — sensor, electronics and firmware — usually in a chamber, at the points that matter for their use.2 min
  11. 11CalibrationHow thermocouples are calibratedThermocouples measure with the whole wire, not just the tip — which is why immersion, homogeneity and the reference junction dominate their calibration.2 min

Questions while you read?

Ask ValiTrac AI — answers cite the standards and show any calculation.