Form · FRM-39
Electrical Calibration Worksheet
Raw data, references and calculations for a DC/LF electrical calibration.
Purpose
The technical record for an electrical calibration under SOP-24: reference calibrator / DMM and their pre-use checks, UUT configuration, warm-up, per-function and per-range readings with applied values, frequency, reference corrections, errors, specification and conformity, uncertainty and checks.
What it covers
- Item details
- Reference standards and equipment
- Environment
- Readings
- Uncertainty and decision rule
- Deviations, observations and nonconforming work
- Checks
- Authorisation
How to complete it
- 1.Record the UUT's configuration (auto-range, filter, averaging) and warm-up time; record the manufacturer's specification edition and confidence level used for conformity.
- 2.For each point record the applied (or measured) reference value, its correction source (certificate interpolation / specification), and two UUT readings.
- 3.Record lead / connection details for low-level and four-wire measurements, and shunt details for high current.
- 4.Record any adjustment and the constants where visible.
Before you use it
- Replace every square-bracket token, starting with [LABORATORY NAME], [ADDRESS] and [EFFECTIVE DATE]. The full token list is in GD-01 Read Me First.
- Have the content technically reviewed against how your laboratory actually works, then approved by the responsible manager before it becomes a controlled document.
- Update the Word fields after editing so the table of contents and page numbers are correct: select all, then press F9.
- Record the document in your own document register and set its review date.
Related documents
- QM-01
Quality Manual
Top-level description of the management system against every clause of ISO/IEC 17025:2017.
- SOP-02
Control of Records and Technical Records
Identification, storage, protection, retention, amendment and disposal of quality and technical records.
- FRM-42
Job File and Technical Record Cover Sheet
Index of every record in a job file so the calibration can be reconstructed.
- FRM-36
Temperature Calibration Worksheet
Raw data, references, environment and calculations for a temperature calibration.
- FRM-37
Humidity Calibration Worksheet
Raw data, references, stabilisation and calculations for a humidity calibration.
- FRM-38
Pressure Calibration Worksheet
Raw data, references, corrections and calculations for a pressure calibration.
- FRM-40
Dimensional Calibration Worksheet
Raw data, references, temperature corrections and calculations for a dimensional calibration.
- FRM-41
Mass and Balance Calibration Worksheet
Raw data for weights and weighing instruments: repeatability, eccentricity, linearity.